p PatchFirst

CVE-2026-133851

CVE-2026-133851 · FlowIntel Alerting: Missing Private Case Authorization Check Allows Connector Owners to Access Revoked Case Data

CVSS 5.3 · Media · EPSS 0,3% · Corrección disponible

Compara con tu versión instalada

Los productos afectados y las versiones corregidas conocidas son datos públicos. Compáralos con tu versión instalada.

Evalúa los riesgos de tu servidor

La comprobación gratuita te da una puntuación y un resumen de riesgos por pila tecnológica, sin registro. No indica si esta vulnerabilidad concreta te afecta.

La monitorización compara los datos públicos con el software de tus servidores. Ofrece hallazgos detallados y el orden de las actualizaciones.

curl -fsSL https://patchfirst.dev/check.sh | sh
Comprobar tu servidor gratis →

Los canales publican noticias generales sobre tecnologías; la monitorización te avisa de nuevos hallazgos en tus servidores en el panel, mediante notificaciones del navegador, en Telegram o por webhook.

Esta página presenta datos de fuentes públicas de vulnerabilidades. Consulta el aviso original antes de actualizar.

FlowIntel's alerting module contained an authorization bypass in the alert access control logic. When an alert was linked to a private case, the system relied solely on connector ownership (user or organization) to determine access, without verifying that the requesting user still held valid membership in the associated private case.

This meant that a user who was a connector owner of an alert could continue to read alert details, review history, raw payloads, and action comments, and could perform review-status updates or case-creation actions, even after their access to the linked private case had been revoked or they were never a member of that case.

Additionally, a time-of-check to time-of-use (TOCTOU) gap existed: after a review-status update or a competing case-creation claim was committed, the response could disclose private case identifiers or review history to a user whose access had been concurrently removed by another session linking the alert to a private case.

Impact:

  • Unauthorized disclosure of private case data (review comments, raw payloads, action history) through alert endpoints.
  • Unauthorized modification of alert review status and creation of cases from alerts the user should no longer access.
  • Leakage of a competing case identifier to an unauthorized user during concurrent case-creation races.

Affected versions: FlowIntel prior to 4.1.0.

Publicación
Actualización

Productos y versiones afectados

  • flowintel

    Versiones
    • ≥ 0, < 4.1.0: Afectada (semver)

    Actualiza a 4.1.0

Fuentes originales

Comprueba tu servidor →