CVE-2026-122247
CVE-2026-122247 · Budibase: Unauthenticated global-admin & database creation via tenant-confusion bypass of the one-time init guard (`POST /api/global/users/init`)
CVSS 8.2 · High · EPSS 0.6% · Public exploit
Compare with your installed version
Affected products and known fixed versions are public information. Compare them with your installed version.
- budibaseNo fix published
- @budibase/server npmNo fix published
Check the installed version:
npm ls @budibase/serverAssess your server’s risks
The free check gives you a rating and a risk summary by technology stack, without signing up. It does not answer whether this particular vulnerability affects you.
Monitoring matches public information against your servers’ software. Detailed findings for your servers include the order of updates.
curl -fsSL https://patchfirst.dev/check.sh | shChannels carry general technology news; monitoring reports new findings on your servers in your dashboard, through browser notifications, in Telegram or via a webhook.
This page contains facts from public vulnerability sources. Check the original advisory before updating.
Budibase is an open-source low-code platform. Prior to 3.50.0, the public POST /api/global/users/init endpoint on a self-hosted single-tenant deployment accepts an attacker-controlled tenantId and evaluates checkAnyUserExists() in the selected tenant database instead of the legitimate default tenant. An unauthenticated attacker can select an unused tenant namespace to bypass the one-time initialization guard, causing packages/worker/src/api/controllers/global/users.ts to create a tenant-specific CouchDB database and a global-administrator document without a session or CSRF token. Repeating this operation with unique tenant identifiers can exhaust datastore resources and leave latent privileged records. The created administrator cannot log into the default tenant while multi-tenancy remains disabled, which limits the immediate impact to persistent writes, denial of service, and records that may become usable during later multi-tenant operation or migration. This issue is fixed in versions 3.50.0 and 4.0.0.
- Published
- Updated
Stack: node
Affected products and versions
budibase
- Versions
- < 3.50.0: Affected
No fix published
@budibase/server npm
- Affected ranges
- SEMVER: ≤ 3.38.1
No fix published
Original sources
- https://github.com/Budibase/budibase/security/advisories/GHSA-25qc-m4pw-2w8r
- https://github.com/Budibase/budibase/commit/362a7fe9aea594531ece1cf15be76cc00bfb88b9
- https://github.com/Budibase/budibase/releases/tag/v3.50.0
- https://github.com/Budibase/budibase/releases/tag/v4.0.0
- https://nvd.nist.gov/vuln/detail/CVE-2026-122247