p PatchFirst

PatchFirst · Latest vulnerabilities

electron 44.3.0: known vulnerabilities

Known vulnerabilities affecting electron 44.3.0: 4. Compare the fixes below with your installed release.

RSS ↗
Filter vulnerabilities
Clear filters

Vulnerabilities: 4

  1. CVE-2026-115570

    High · CVSS 7.4Fix available

    Electron: Mitigation for compromised eMudhra intermediate certificates

    Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to 42.11.16, 43.8.1, 44.9.1, and 45.0.0-beta.6, Electron does not block compromised eMudhra intermediate certificates in Chromium networking, Node.js tls, Node.js https, or Node.js fetch. An attacker who holds a certificate issued through one of these intermediates and can intercept network traffic can impersonate a TLS server to an affected application. This issue is fixed in versions 42.11.16, 43.8.1, 44.9.1, and 45.0.0-beta.6.

    • Update to 44.9.1
    Published Updated
  2. CVE-2026-114124

    Low · CVSS 3.9EPSS 0.15%Fix available

    Electron: Off-screen rendering on macOS trusts GPU-supplied frame geometry

    Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 42.11.6, 43.7.3, 44.4.3, and 45.0.0-alpha.9, frame data received from the GPU process for macOS offscreen rendering was not fully validated by the main process. An attacker who had separately gained code execution in the GPU process could provide inconsistent frame geometry and cause the main process to read out-of-bounds memory while producing paint event images, disclosing memory or crashing the application. This issue is fixed in versions 42.11.6, 43.7.3, 44.4.3, and 45.0.0-alpha.9.

    • Update to 44.4.3
    Published Updated
  3. CVE-2026-114122

    Low · CVSS 3.9EPSS 0.14%Fix available

    Electron: Frame subscription trusts GPU-supplied frame geometry

    Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 42.11.6, 43.7.3, 44.4.3, and 45.0.0-alpha.9, frame data received from the GPU process for webContents.beginFrameSubscription was not fully validated by the main process. An attacker who had separately gained code execution in the GPU process could supply inconsistent frame geometry and cause the main process to read out-of-bounds memory while producing captured frame images, disclosing memory or crashing the application. This issue is fixed in versions 42.11.6, 43.7.3, 44.4.3, and 45.0.0-alpha.9.

    • Update to 44.4.3
    Published Updated
  4. CVE-2026-113798

    Medium · CVSS 5.4EPSS 0.21%Fix available

    Electron: Pointer lock permission requests can be attributed to the wrong frame

    Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 42.11.9, 43.7.6, 44.5.0, and 45.0.0-alpha.13, pointerLock permission requests from some cross-origin iframes caused session.setPermissionRequestHandler() to receive the top-level frame's requestingUrl and isMainFrame values instead of those of the requesting frame. An application that embeds untrusted iframe content and grants pointer lock based on the requesting origin could therefore grant the permission under the top-level page's identity. Applications that deny pointerLock for untrusted embedded content are not affecte

    • Update to 44.5.0
    Published Updated

Check your server

Check your installed stack and versions against the current vulnerability feeds.

Check your server →